// Formula: Frequency = Pulses per second = FlowRate(L/min) * 7.5 // So: FlowRate = Pulses / 7.5 flowRate = pulseCount / 7.5;
The library creator might have used a different K-factor. Real YF-S201 K-factors vary between 450 and 520 pulses per liter. Edit the library properties (Right-click → Edit Properties) to adjust the PulsePerLiter parameter if exposed. yf-s201 proteus library
Have you used the YF-S201 library in an innovative way? Found a better calibration method? Share your experience in the comments below (and consider uploading your working simulation file to the community). Happy simulating! // Formula: Frequency = Pulses per second =
As of the writing of this article, the most reliable sources are: Have you used the YF-S201 library in an innovative way
Here’s what you can do:
Since Proteus does not have a native YF-S201 model, you can simulate its behavior using these methods: Pulse Generator: Because the sensor outputs a square wave pulse, use a